| ERH Pilot Test for Remediation of TCE DNAPL |
| U.S. Naval Air Station Dallas, Texas |
|
| Contaminants of Concern: |
TCE |
| Starting Contaminant Levels: |
DNAPL |
| Geology: |
Fill, clay, silt, and gravel |
| Hydrology: |
Groundwater at 6 feet bgs |
| Remediation Design Engineers: |
Mr. Greg Beyke, Mr. Jerry Wolf |
| Operations Manager: |
Mr. Jerry Wolf |
| Current Project Status: |
Presently at the initial design stage |
| Scheduled Completion Date: |
Summer 2003 |
TRS was retained to design, construct and operate an ERH pilot test at the Naval Air Station in Dallas, Texas (NAS). TRS is presently completing the design and preparing to mobilize our ERH specialty equipment to the site. Once the pilot test has been successfully completed, the treatment system will be expanded to remediate a larger area. The goal of the pilot test is a 99% reduction in TCE concentrations in soil and groundwater.